{"id":1664,"date":"2018-10-04T20:52:16","date_gmt":"2018-10-04T20:52:16","guid":{"rendered":"http:\/\/www.romanopisciotti.com\/?p=1664"},"modified":"2018-10-04T20:52:36","modified_gmt":"2018-10-04T20:52:36","slug":"anesthesia-workstation","status":"publish","type":"post","link":"https:\/\/www.romanopisciotti.com\/index.php\/2018\/10\/04\/anesthesia-workstation\/","title":{"rendered":"Anesthesia Workstation"},"content":{"rendered":"<div class=\"page\" title=\"Page 1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<h3><strong>A9800<\/strong><\/h3>\n<div class=\"page\" title=\"Page 1\">\u00a0<a href=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1666\" src=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/1-209x300.png\" alt=\"\" width=\"324\" height=\"465\" srcset=\"https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/1-209x300.png 209w, https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/1.png 445w\" sizes=\"auto, (max-width: 324px) 100vw, 324px\" \/><\/a><\/div>\n<h1>Anesthesia Workstation<\/h1>\n<\/div>\n<\/div>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Your healthcare, we care.<\/p>\n<h3>In Nigeria by Romano Pisciotti<\/h3>\n<h3>ITALMOTOR Ltd<\/h3>\n<h3><strong>A9800 Anesthesia Workstation<\/strong><\/h3>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><strong>A9800 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and\u00a0electronically controlled ventilation.<\/strong><\/p>\n<p>It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician.<br \/>\nA9800 incudes Adult and Child modes that provide patient-appropriate defaults and ranges.<\/p>\n<p>A9800 provides complete anesthesia ventilation capabilities that include traditional and \u201cintensive-care type\u201d ventilation modes like PCV-VG (volume guarantee). Low-flow anesthesia delivery creates savings by lowering facility gas usage. Sophisticated ventilation capabilities of A9800 will meet the needs of the full patient range. The integrated Electronic flowmeter provides accurate monitoring and intuitive operation.<\/p>\n<p><strong>Abundant options for A9800<\/strong><\/p>\n<p>Gas monitoring CO2, N2O &amp; 5 types of anesthetic agents. AGSS (Anesthetic Gas Scavenging System) provides safe and effective waste gas removal.<br \/>\nPatient suction regulator.<\/p>\n<p>Third vaporizer parking position.<\/p>\n<p><a href=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.17.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1667\" src=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.17-300x283.png\" alt=\"\" width=\"300\" height=\"283\" srcset=\"https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.17-300x283.png 300w, https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.17.png 550w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"page\" title=\"Page 3\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><strong>A9800 Anesthesia Workstation<\/strong><\/p>\n<p>Advanced and clear user interface:<\/p>\n<p>The large 15\u201d TFT LCD with touch screen along with a navigator wheel provides a simple intuitive interface that enhances user control. The screen can be tilted upward and downward according<br \/>\nto the doctor\u2019s needs and position. These ergonomic features assure the clinician can complete the entire operation easily and accurately. The parameter areas on the main screen are shown in different\u00a0colors for ease of identification. The waveforms and alarm records are clearly shown for easy review by the clinician of the patient\u2019s treatment information.<\/p>\n<p>Powerful monitoring functions:<\/p>\n<p>A9800 displays patient data with waveforms and spirometry loops. Loops can be stored as reference to best understand changes in patient response to therapy. Optional gas monitoring provides clinicians with complete information on patient ventilation and agent delivery and uptake.<\/p>\n<p>The Electronic flow meters for O2, Air and N2O are designed especially for low-flow applications. This system includes electronic fresh gas flow displays along with traditional mechanical flow controllers and flow control knobs for enhanced patient safety<br \/>\nover fully electronic blending systems.<br \/>\nData communications export is supported to connect to the<br \/>\nHospital IT systems and support EMR.<\/p>\n<p><a href=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.57.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1668\" src=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.57-300x201.png\" alt=\"\" width=\"300\" height=\"201\" srcset=\"https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.57-300x201.png 300w, https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.39.57.png 597w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><strong>A9800 Anesthesia Workstation<\/strong><\/p>\n<p>Full Featured Workstation:<br \/>\nAdvanced features for therapy delivery are also easy to use. The single-turn APL valve on A9800 includes a quick-release function to quickly lower patient breathing pressure and accurately sets pressure limits<br \/>\nAutomatic Compliance compensation along with Fresh Gas Flow compensation help clinician to deliver accurate and precise ventilation therapy<br \/>\nFull waveform display including integrated Spirometry provides loops when desired for improved clinical data analysis<br \/>\nSystem provides a minimum of 25% O2 concentration at all times utilizing a pneumatic Oxygen Ratio Controller. This enhances patient safety over systems that utilize electronic or software controlled ORC functions<br \/>\nLarge stainless worktable provides extra convenience to the user, with the flip- up table design saving space efficiently<br \/>\nImpressive array of standard features improves the system usability: auxiliary oxygen flow meter with Air\/O2 Blender and auxiliary AC power outlets<br \/>\nAir\/O2 Blender for Aux Gas outlet is conveniently located on front panel to allow user to mix Aux Gas from 100% O2 to 21% O2 easily and accurately<br \/>\nBreathing system is heated to reduce condensation and is integrated within the workstation<br \/>\nAdvanced breathing system is fully autoclaveable<br \/>\nAbsorber by-pass function makes changing absorbent during a case easier Absorber is compatible with Standard Prepaks or loose-fill CO2 Absorbent Auto\/Manual Switch is located on the breathing system for simple control of Ventilator On\/Off<br \/>\nACGO (Auxiliary Common Gas Outlet) switch is a standard feature to allow for use with non-rebreathing adapters<br \/>\nGCX-type rails support easy mounting of other devices to the workstation<br \/>\n6 Traditional Gas Supply Pressure Gauges allow for easy status monitoring of hospital wall gas supplies and gas cylinders\/tanks<br \/>\n3 locking drawers for storage<br \/>\nStandard SelectatecTM-compatible mounts hold two vaporizers<\/p>\n<p><a href=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.40.15.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1669\" src=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.40.15-300x192.png\" alt=\"\" width=\"380\" height=\"243\" srcset=\"https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.40.15-300x192.png 300w, https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/Schermata-2018-10-04-alle-21.40.15.png 631w\" sizes=\"auto, (max-width: 380px) 100vw, 380px\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"page\" title=\"Page 5\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><strong>A9800 Anesthesia Workstation Technical Parameters<\/strong><\/p>\n<p>Ventilation Modes<\/p>\n<p>\u00b7Volume Control<br \/>\n\u00b7Pressure Control<br \/>\n\u00b7SIMV with Pressure Support (SIMV + PS) &#8211; with Volume or<\/p>\n<p>Pressure-type mandatory breaths<br \/>\n\u00b7Pressure Support (with Apnea backup)<br \/>\n\u00b7PCV-VG (Pressure Control Ventilation with Volume Guarantee) \u00b7Manual ventilation<\/p>\n<p>Parameters and Ranges<\/p>\n<p>\u00b7Pressure target: 5 \u2013 70 cmH2O \u00b7Pressure support (delta P): 3 \u2013 50 cmH2O \u00b7Tidal Volume: 20 \u2013 1500 mL<br \/>\n\u00b7Breathing Freq.: 2-100 bpm<\/p>\n<p>2-60 bpm in PS<br \/>\n2-100 bpm in SIMV-VC and SIMV-PC 4-100 bpm in other modes<\/p>\n<p>\u00b7TINSP: 0.2-5.0 s<br \/>\n\u00b7PEEP: OFF, 3 &#8211; 30 cmH2O<br \/>\n\u00b7FreqMIN: 2 &#8211; 60 bpm<br \/>\n\u00b7T pause: OFF, 5%-60%<br \/>\n\u00b7Trigger: 1 \u2013 15 L\/min<br \/>\n\u00b7I:E Ratio: 4:1-1:8<br \/>\n\u00b7TSLOPE: 0 \u2013 2 s<br \/>\n\u00b7Vaporizers: Sevoflurane, Desflurane, Isoflurane, Halothane,<\/p>\n<p>Enflurane<\/p>\n<p>Monitoring<\/p>\n<p>\u00b7Continous monitoring of inspiratory O2 concentration, breathing frequency, airway pressure (Paw, Peak, Pmean, PEEP), minute volume and tidal volume.<\/p>\n<p>\u00b7The measured parameters are displayed as large, easy to read digital values. Airway pressure, flow and CO2 (optional) are shown in graphical waveforms.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"page\" title=\"Page 6\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Alarms<\/p>\n<p>\u00b7Apnea<br \/>\n\u00b7Apnea CO2<br \/>\n\u00b7Adjustable alarm limits for Inspiratory O2 concentration (FiO2) \u00b7Adjustable alarm limits for Minute Volume (MV)<br \/>\n\u00b7Adjustable alarm limits for Airway pressure (PAW) \u00b7Adjustable alarm limits for EtCO2 and agents<br \/>\n\u00b7Continuous Pressure<br \/>\n\u00b7O2 Supply Fail<br \/>\n\u00b7Negative Pressure<br \/>\n\u00b7High Breath Rate (PS)<br \/>\n\u00b7High PEEP<br \/>\n\u00b7Mixed Agents<br \/>\n\u00b7Low Battery<br \/>\n\u00b7AC Power Fail<br \/>\n\u00b7Technical alarms<\/p>\n<p>Operation Conditions<\/p>\n<p>\u00b7Operating voltage: AC100-240V, 50Hz\/60Hz<br \/>\n\u00b7Temperature: 10 &#8211; 40\u00b0C(operation); -20 &#8211; 60\u00b0C (storage &amp;transport) \u00b7Relative humidity: \u226490%, non-condensing (operation);<\/p>\n<p>\u226490%, non-condensing(storage &amp;transport) \u00b7Weight (without vaporizer &amp; cylinders): approx. 100Kg<\/p>\n<p>\u00b7Dimensions (H x W x D): approx. 1400mm x 900mm x 760mm<\/p>\n<p><strong>Standards<\/strong><\/p>\n<p><strong>EN 60601-1, EN 60601-1-2, ISO 80601-2-13<\/strong><\/p>\n<figure id=\"attachment_1665\" aria-describedby=\"caption-attachment-1665\" style=\"width: 300px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/MediCare-srl.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1665\" src=\"http:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/MediCare-srl-300x231.png\" alt=\"\" width=\"300\" height=\"231\" srcset=\"https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/MediCare-srl-300x231.png 300w, https:\/\/www.romanopisciotti.com\/wp-content\/uploads\/2018\/10\/MediCare-srl.png 475w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-1665\" class=\"wp-caption-text\">MediCare srl<\/figcaption><\/figure>\n<h3>In Nigeria by Romano Pisciotti<\/h3>\n<h3>ITALMOTOR Ltd.<\/h3>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A9800 \u00a0 Anesthesia Workstation Your healthcare, we care. In Nigeria by Romano Pisciotti ITALMOTOR Ltd A9800 Anesthesia Workstation A9800 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and\u00a0electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9800 &hellip; <a href=\"https:\/\/www.romanopisciotti.com\/index.php\/2018\/10\/04\/anesthesia-workstation\/\" class=\"more-link\">Continua a leggere <span class=\"screen-reader-text\">Anesthesia Workstation<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":1665,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[14,621],"tags":[1202,1204,158,1205,639,5,41,1203],"class_list":["post-1664","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-marketing","category-pisciotti","tag-anesthesia","tag-anesthesia-workstation","tag-italmotor","tag-medi-care","tag-nigeria","tag-pisciotti","tag-romano-pisciotti","tag-workstation"],"_links":{"self":[{"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/posts\/1664","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/comments?post=1664"}],"version-history":[{"count":1,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/posts\/1664\/revisions"}],"predecessor-version":[{"id":1670,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/posts\/1664\/revisions\/1670"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/media\/1665"}],"wp:attachment":[{"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/media?parent=1664"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/categories?post=1664"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.romanopisciotti.com\/index.php\/wp-json\/wp\/v2\/tags?post=1664"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}